XStreamPKGT™TelephoneRFModemProductManualv5.x00[2006.02.24]
Binary Command Example
The following example steps through an RF module configuration process using binary
commands.
To Send Binary Commands:
Example: Use binary commands to change the RF Module’s destination address to 0x1A0D and
save the new address to non-volatile memory.
1. RT Command must be set to “1” in AT Command Mode to enable binary programming.
2. Assert CMD (Pin is driven high). (Enter Binary Command Mode)
3. Send Bytes [Parameter bytes must be 2 bytes long]:
00 (Send DT (Destination Address) Command)
0D (Least significant byte of parameter bytes)
1A (Most significant byte of parameter bytes)
08 (Send WR (Write) Command)
4. De-assert CMD (Pin is driven low). (Exit Binary Command Mode)
Note: is high when command is being executed. Hardware flow control must be disabled as
will hold off parameter bytes.